Feature:
·Resolution up to 1/15000
·Single point and linear calibration available
·Hold function in peak, stability, or key operation
·Lower/upper limit weighing alarming function
·Zero range setting and filter setting for counting under various condition
·Accumulation, Accumulation Display and Accumulation clear functions
·RS-232/Relay/Blue Tooth/U-KEY connector/WP wireless print/U-disk module/ Wifi/Ethernet (optional)
·Ideal for applications in production, packaging, warehouse, inventory, shipping and receiving areas
Specifications:
Model |
JWQ-3K |
JWQ-6K |
JWQ-15K |
JWQ-30K |
Capacity(kg) |
3 |
6 |
15 |
30 |
Division(g) |
0.2 |
0.5 |
1 |
2 |
Display screen |
128X51mm |
|||
Dimension(mm) |
275X290X110 |
|||
Weighing units |
kg, g, t, lb, oz, pcs, 斤(台斤,港斤,市斤) |
|||
Weighing pan(mm) |
275x 190(Stainless Steel, and 1.0mm in thickness) |
|||
Power supply |
AC 100~240V / rechargeable battery (6 V/ 4 AH) |
How important is it to quickly troubleshoot electronic weighing scales?
Electronic weighing scales are delicate instruments that consist of many components. Problems with each part or even each wire can cause inaccuracies, large errors, and non-display of values. It is important to quickly determine the cause of the electronic scale failure and to quickly investigate the cause and restore it to use.
How to handle troubleshooting and error messages of JWQ?
Error Message |
Problem |
shootings |
ERR0 |
Exceed the zero range |
The item should be within 2% of full load |
ERR2 |
Exceed the initial zero point |
1. Check whether there are other alien articles on the scale pan, remove those articles. 2. LOAD CELL failure, which requires to be changed or to contact our Service. |
ERR3 |
Exceed the A/D resolution range |
1. Check whether it is A/D failure, if yes, please replace AD. 2. LOAD CELL failure, replacement is required or contact our Service. |
ERR4 |
EEPROM failure |
Re-sold EEPROM or contact our Service. |
ERR5 |
Overload condition |
Remove weight that is greater than the scale capacity from the pan. |
ERR6 |
Exceeds the display range |
-------------------------------------------- |
ERR7 |
Accumulated number of weights exceeds the display range |
Delete the exceeding weights |
ERR8 |
Weight limit value is higher than the full load value |
Reset the weight limit value. |
ERR9 |
Exceed tare or pre-tare range |
The tare value should be over zero and less than or equal to full load. |
ERR10 |
Wrong calibration weights |
Place the right weights( the calibration value ≤ full load) |